1.4.2 Action at an alarm occurrence
Display the alarm occurrence indication button on the “Live” page
IMPORTANT
•
When “Polling(30s)” is selected for “Status update mode” (→
2.4.1 Configure the basic settings [Basic]), the Alarm occurrence indication button will be refreshed in 30-second intervals. For this reason, it may take a maximum of 30 seconds until the alarm occurrence indication button is displayed on the “Live” page at an alarm occurrence.
Notify of alarm occurrences to the device connected to the output terminal
Save images on the SD memory card
Transmit an image onto a server automatically
Notify of alarm occurrences by E-mail
Notify of alarm occurrences to the designated addresses (Panasonic alarm protocol notification)
This function is available only when a Panasonic device, such as the network disk recorder, is connected to the system. When “On” is selected for “Panasonic alarm protocol”, the connected Panasonic device will be notified that the camera is in the alarm state. The settings for Panasonic alarm protocol can be configured in the “Panasonic alarm protocol notification” section of the [Notification] tab of the “Alarm” page. (→
2.7.8.1 Configure the settings relating to Panasonic alarm protocol)
Notify of alarm occurrences to the designated HTTP server (HTTP alarm notification)
Alarm occurrence notifications can be sent at an alarm occurrence to the HTTP servers registered in advance. Up to 5 HTTP servers can be registered as recipients of alarm notifications. The URL sent to HTTP servers with alarm notifications can be specified. The settings for HTTP alarm notification can be configured on the [Notification] tab of the “Alarm” page. (→
2.7.8.2 Configure the settings relating to HTTP alarm notification)