The settings relating to the output terminal can be configured in this section.
Output terminal
In order to be able to configure “Output terminal”, “Alarm output” must be selected for [Terminal 2] of the [Alarm] setting.
[Terminal output upon alarm detection]
Select “On” or “Off” to determine whether or not to output the alarm signals to the output terminal when an alarm is detected.
[SD memory card error]
Select “On” or “Off” to determine whether or not to output signals from the output terminal when an error is detected for the SD memory card.
SD memory card error condition: SD memory card error (write error, read error, etc), Total use time over 6 years, and number of overwrites over 2000 times
•
On: When an error status is detected, the signals from an output terminal is outputted and the [Alarm occurrence indication] button on the “Live” page blinks.
•
Off: Deactivates the warning status detection.
IMPORTANT
•
In order to be able to correctly use this function, format the SD memory card with the camera before using it.
Note
•
The total service time of 6 years is the total power-on time from the SD card being inserted. 2000 cycles are the upper limit overwrite counts of the industrial SD memory card (MLC type). These are typical values and not a guarantee of the SD card lifetime.
•
The output terminal and the SD memory card errors use the same output terminal.
•
A signal is outputted to the output terminal when either an alarm or SD memory card error occurs.
•
When an SD memory card error is detected, the [Alarm occurrence indication] button on the “Live” page blinks. If you click on the [Alarm occurrence indication] button, the button will be hidden.
•
Output signals from the output terminal for [SD memory card error] differ depending on the settings of [Terminal state upon alarm detection].
–
When “Latch” is selected: Even after you click the [Alarm occurrence indication] button and it disappears, output signals from the output terminal will continue as long as the cause of the [SD memory card error] is not resolved.
–
When “Pulse” is selected: Even after you click the [Alarm occurrence indication] button and it disappears, output signals from the output terminal will continue as long as the cause of the [SD memory card error] is not resolved. However, if the time period specified for [Pulse output width] is exceeded, output signals from the output terminal will be stopped.
[Terminal state upon alarm detection]
Select “Latch” or “Pulse” for the output terminal at an alarm occurrence.
•
Latch: When an alarm is detected, the output terminal will be in the state selected for “Terminal action upon alarm detection” until the alarm occurrence indication button is clicked.
•
Pulse: When an alarm is detected, the output terminal will be in the state to the “Terminal action upon alarm detection” setting for the period set for “Pulse output width”. When the alarm occurrence indication button is clicked, the output terminal will return to the normal state.
[Terminal action upon alarm detection]
Select “Open” or “Close” to determine whether to open or close the output terminal when outputting the alarm signals.
•
Open: The output terminal will open when outputting the alarm signals. (Normally close)
•
Close: The output terminal will close when outputting the alarm signals. (Normally open)
Note
•
When “Open” is selected, the alarm signal will be output for about 20 seconds when the power of the unit is turned on.
[Pulse output width]
When “Pulse” is selected for “Terminal state upon alarm detection”, select an output terminal duration from the following.
•
Available range: 1-120s